Four high performance
units give coverage for the VHF Channels 7-13 and UHF TV Bands 470
- 860 MHz. Optimized for LOW LOSS, these circulators typically
operate at 500 Watts cw, 900 Watts peak power level. |
| |
| |
The units
are designed for efficient heat transfer, however heat sinking must
be adequate to transfer the internally dissipated power (from less
than 25 Watts in the circulator to about 150 watts for the isolator
absorbing rated reverse power.) The forward power rating may
be raised by providing adequate heat sinking to keep the circulator
body temperature within the rated temperature range of -10°C
to + 70°C
and will not be damaged by even greater temperature extremes (-30°C to + 90°C). |
| |
| |
The isolator version has an integral 125 Watt
loaded designed to provide a minimum of 20 dB isolation. |
| |
|
Typical
Specifications |
Isolation: |
|
20 dB min |
| Insertion
Loss: |
|
0.25
dB max 0.12 dB typ |
| VSWR: |
|
1.20
: 1 max |
| Temp.
Range: |
|
-10°C
to + 70°C |
| Size: |
|
2-3/4
x 2-15/16 x 1-1/4 |
| Connectors: |
|
N
- Fe standard
DIN 7/16 special order |
|
|
|
| Channels |
Frequency |
Circulator |
Isolator |
Size |
| 7-10 |
174-200
MHZ |
CT-1682-N |
|
3.5x3.5x1.25 |
| 11-13 |
200-220
MHZ |
CT-1683-N |
|
|
| 14
- 26 |
470
- 548 MHz |
CT-1325-N |
CT-1345-NT |
|
| 26
- 44 |
542
- 656 MHz |
CT-1326-N |
CT-1346-NT |
|
| 44
- 69 |
650
- 806 MHz |
CT-1327-N |
CT-1347-NT |
|
| 69
- 78 |
800
- 860 MHz |
CT-1328-N |
CT-1348-NT |
|
|
| |
| |
Low Frequency/Common
Bands |
|
These units cover most common frequency
ranges at power levels of 100 Watts cw or average.
They are also available for any specific ranges you designate. |
| |
|
Typical Specifications
|
Isolation: |
|
20 dB min |
| Insertion
Loss: |
|
0.40
dB max |
| VSWR: |
|
1.25
: 1 max |
|
|
| |
|
SMA (F) Connectors |
N (F) Connectors |
|
| Frequency Range (MHz) |
Isolator
Model No. |
Circulator
Model No. |
Isolator
Model No. |
Circulator
Model No. |
Housing
Size(inches) |
340
- 365
400 - 450
450 - 515 |
CT-1230-OT
CT-1130-OT
CT-1249-OT |
CT-1163-O
CT-1128-O
CT-1248-O |
CT-1231-NT
CT-1129-NT
CT-1251-NT |
CT-1161-N
CT-1126-N
CT-1250-N |
3-1/2
x 3-1/2 x 1-1/4
2-1/2 x 2-1/2 x 1
2 x 2 x 1 |
470 - 560
560 - 675
670 - 810 |
CT-1253-OT
CT-1257-OT
CT-1261-OT |
CT-1252-O
CT-1256-O
CT-1260-O |
CT-1255-NT
CT-1259-NT
CT-1263-NT |
CT-1254-N
CT-1258-N
CT-1262-N |
2 x 2 x 1
2 x 2 x 1
2 x 2 x 1 |
755
- 985
800 - 960
960 - 1225 |
CT-1057-OT
CT-1059-OT
CT-1061-OT |
CT-1058-O
CT-1060-O
CT-1062-O |
CT-1045-NT
CT-1047-NT
CT-1247-NT |
CT-1046-N
CT-1048-N
CT-1223-N |
2
x 2 x 1
1-5/8 x 1-5/8 x 1
1-5/8 x 1-5/8 x 1 |
|
|
High cw or average power units are also
available for your specific applications. |
| |
 |
|